Skip to main content

SPRG0077

Education Program Membership Start Date Less Than Student School Start Date

Severity
FATAL error - Must be corrected in order to post the record and/or certify your data.

Error Description

If Education Program Membership Code equals 3 (Participating), then Education Program Membership Start Date must be greater than or equal to first Student School Start Date in CALPADS

Suggested Resolution

1) Change either the Education Program Membership Start Date or Student School Start Date to the accurate date(s) and sequence to resolve this error.

OR

2) If the Education Program Membership Code is incorrectly populated in the submission, change it so the correct value is submitted to CALPADS for the student program record of the SSID. See http://www.cde.ca.gov/ds/sp/cl/systemdocs.asp for the CALPADS Code Sets and File Specifications documents.

Fields Validated

1.23 - Student School Start Date

3.15 - Education Program Membership Start Date



Headache Factor

SPRG0077



Tags
0077 - 77 - CALPADS - Education Program Membership - Enrollment - ERROR - FALL 1 - SPRG - SPRG0077 - Student Program

Solution Rating
5.0/5 rating 1 vote
Cron Job Starts